The
Electronic Static Weigh-bridge is made up of a framework
of girders adequately reinforced with transverse
beams and suitable non-slip top deck with Pit less
& Pit type Structure. The entire steel framework
is mounted on strain gauge double ended shear beam
/ Compression Type Load Cells (4, 6, & 8 No's.
Load Cells), depending on length of the platform.
The shear stress produced by the load is detected
by a strain gauge, full bridge circuit and converted
into an analog electrical signal. Signal from each
loadcell is fed to Junction Box. Output from Junction
Box is fed to microprocessor based weighbridge Microprocessor
based weighbridge Intelligent Terminal. The processing
electronics of terminal digitizers the signal from
the Junction-box using an ADC, based on time proven
quad slope integration technique and weight is registered
on LED display.
SIZE
AND CAPACITIES
Platform
Size( Mtr.)
Capacity
(Ton)
Graduation
(kg)
Number
of
Load cells
Size
of Capacities
4.5
X 2.5
10
2
Kg.
4
6
X 2.5
20
2
Kg.
4
7.5
X 3
30
5
Kg.
4
All
models are available from
8X3
30/40
5
Kg.
4
7.5
X 3m. up to
20 X 3m.
9X3
40/50
5
Kg.
4
Standard
capacities range from
1OX3
40/50
5
Kg.
4
20,000
up to
1,00,000 Kg Other
12
X 3
50
5
Kg.
6
Platform
sizes and capacities also
14
X 3
50/60
10
Kg.
6
possible
to suit individual requirements
15X3
50/60
10
Kg.
6
and
regulations. Load cell range
16
X 3
50/60
10
Kg.
6
includes
explosion proof
18X3
60/80/100
10
Kg. / 20 Kg
8
load
cells also.
20X3
80/100
10
Kg. / 20 Kg
8
*
Specifications subject to change without notice
Features :
Modular
Form
Parallel
out put to printer
96
KB switching memory battery backed
22
KB system software
Built
in real time clock
100
year software calendar to display day, date, month,
year, hours & mintures.
16
character single line & 20 character double
line LCD module for user dialogue in a
question / answer form.